MIL-C-39019/4

Circuit Breakers

CIRCUIT BREAKER

MIL-C-39019/4

5925-01-096-4702

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specification/Standard Data

    81349-mil-c-39019/4 government specification

  • Terminal Type And Quantity

    4 wire hook

  • Unpackaged Unit Weight

    100.0 grams

  • Frequency In Hertz

    400.0

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Switch Location And Position Designation

    internal at pole two

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    instantaneouss

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    1.797 inches minimum and 1.828 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.653 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Body Width

    1.250 inches minimum and 1.281 inches maximum

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Thread Series Designator

    unef

  • Test Data Document

    81349-mil-c-39019 specification

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Actuator Position Designation

    between pole one and two

  • Reset Method

    manual

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc

  • Switch Contact Arrangement

    single pole,double throw

  • Case Material

    metal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...