TED134C5080
Circuit Breakers
CIRCUIT BREAKER
TED134C5080
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Frequency In Hertz
60.0 single location
-
Trip Release Characteristic
instantaneous single location
-
Case Material
plastic
-
Pole Quantity
3
-
Body Style
rectangular dimensional envelope
-
Reset Method
manual
-
Overall Width
4.125 inches nominal
-
Actuator Function
trip-reset
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac single location
-
Overall Length
6.312 inches nominal
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
-
End Item Identification
ships service switchboard onboard 140 ft wtgb coast guard vessels
-
Circuit Protection Type
overcurrent single location
-
Unthreaded Mounting Hole Diameter
0.250 inches nominal
-
Actuator Position Designation
at pole two
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Release Method
thermal-magnetic single location
-
Terminal Type And Quantity
6 compression
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac single location
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac single location
-
Overall Height
3.812 inches nominal