0N535928-2

Circuit Breakers

CIRCUIT BREAKER

0N535928-2

5925-01-097-1741

5925 - Circuit Breakers

National Security Agency

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac first location and 1.0 amperes dc first location

  • Terminal Type And Quantity

    4 wire hook

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Unpackaged Unit Weight

    100.0 grams

  • Mounting Surface To Terminal End Distance

    1.760 inches maximum

  • Body Width

    1.250 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.250 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac second location and 250.0 milliamperes dc second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...