Technical Characteristics

  • Body Length

    2.475 inches minimum and 2.505 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.045 inches minimum and 2.075 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt water resistant

  • Unpackaged Unit Weight

    4.250 ounces

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Mounting Surface To Terminal End Distance

    2.445 inches minimum and 2.475 inches maximum

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct and 1.800 maximum at 200 pct

  • Frequency In Hertz

    50.0 or b60.0

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...