412D6782
Relays and Solenoids
RELAY,ELECTROMAGNETIC
412D6782
Teledyne Technologies Incorporated
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Diameter
0.370 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load
-
Arc Quenching Method
air
-
Special Features
failure rate 3.0
-
Winding Quantity
1
-
Operating Voltage Rating And Type At Specified Temp
12.0 volts teardrop, two holes type 4f single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes dc lamp load
-
Environmental Protection
shock resistant and vibration resistant
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Terminal Type And Quantity
9 pin all functions
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
200.0 milliamperes dc inductive load
-
Overall Length
0.280 inches maximum
-
Duty Type
continuous
-
Mounting Facility Type And Quantity
1 plug-in terminal single mounting facility
-
Fragility Factor
moderately rugged
-
Test Data Document
12436-6010157 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Dc Resistance Rating
390.0 ohms nominal single winding
-
Cubic Measure
0.030 cubic inches
-
Criticality Code Justification
feat
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary