7756250

Circuit Breakers

CIRCUIT BREAKER

7756250

5925-01-098-2084

5925 - Circuit Breakers

Ogden Air Logistics Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1a single pole type

  • Body Length

    1.750 inches nominal

  • Body Width

    0.656 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    1.718 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac and 50.0 milliamperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and 30.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 2500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

  • Bushing Length

    0.290 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.145 inches nominal

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32.0

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Reset Method

    manual

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.469 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct and 20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    7.0 ac and 4.0 dc

  • Switch Voltage Rating And Type In Volts

    230.0 ac and 28.0 dc

  • Frequency In Hertz

    60.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...