10527-3

Circuit Breakers

CIRCUIT BREAKER

10527-3

5925-01-099-9538

5925 - Circuit Breakers

Alliant Techsystems Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac all locations and 1.5 amperes dc all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and salt spray proof and humidity resistant and corrosion resistant and shock resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Body Width

    1.250 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Bushing Length

    0.380 inches maximum

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...