JA3-Z18-6
Circuit Breakers
CIRCUIT BREAKER
JA3-Z18-6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
6 threaded hole
-
Boss Height
0.125 inches minimum and 0.135 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Body Width
2.245 inches minimum and 2.255 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Width
0.745 inches minimum and 0.755 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Terminal Type And Quantity
6 tab w/screw
-
Manual Actuator Type And Quantity
3 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.500 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations
-
Switch Location And Position Designation
internal at pole one
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.745 inches minimum and 0.755 inches maximum
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
33.0 amperes ac all locations
-
Inclosure Protection Type For Which Designed
dustproof
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Mounting Surface To Terminal End Distance
1.835 inches minimum and 1.845 inches maximum
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
-
Switch Voltage Rating And Type In Volts
125.0 ac and 28.0 dc
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations