JB2S-A3-A-15-3

Circuit Breakers

CIRCUIT BREAKER

JB2S-A3-A-15-3

5925-01-101-9479

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Terminal Type And Quantity

    4 quick disconnect, male

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    1.718 inches minimum and 1.782 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Body Height

    1.811 inches minimum and 1.875 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Facility Type And Quantity

    4 clip

  • Unpackaged Unit Weight

    5.000 ounces

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Length

    2.418 inches minimum and 2.482 inches maximum

  • Boss Height

    0.093 inches minimum and 0.157 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 1.500 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.923 inches minimum and 0.987 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...