3591414-1

Circuit Breakers

CIRCUIT BREAKER

3591414-1

5925-01-102-5591

5925 - Circuit Breakers

Honeywell Intl Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Body Length

    2.490 inches nominal

  • Body Width

    2.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.940 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Boss Height

    0.150 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.755 inches maximum

  • Storage Type

    general purpose warehouse

  • Features Provided

    high inrush protection

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Auxiliary Switch Function And Quantity

    3 alarm

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct and 9.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and shock resistant and vibration resistant

  • Switch Terminal Type

    quick disconnect,male

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Frequency In Hertz

    50.0 or b60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...