Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    1.480 inches minimum and 1.520 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.850 inches maximum

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc second location

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    instantaneous second location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    relay trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct first location

  • Special Features

    pole 2 circuit protection type is major voltage loss or no voltage

  • Frequency In Hertz

    50.0 first location or 60.0

  • Unpackaged Unit Weight

    6.500 ounces

  • Terminal Type And Quantity

    6 threaded stud

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    4 clip

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    107.0 dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Circuit Protection Type

    overcurrent first location

  • Trip Release Characteristic

    time delay first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one and two linked

  • Internal Trip Release Configuration

    series trip first location

  • Inclosure Protection Type For Which Designed

    general purpose

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...