583-99-TC-K14-25A

Circuit Breakers

CIRCUIT BREAKER

583-99-TC-K14-25A

5925-01-104-4624

5925 - Circuit Breakers

Oakland Industries Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Body Height

    1.500 inches maximum

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches nominal

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Bushing Length

    0.281 inches nominal

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations and 25.0 amperes dc all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Body Width

    0.850 inches nominal

  • Trip Release Method

    thermal all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations and 28.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations and 2500.0 dc all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...