1618-13

Circuit Breakers

CIRCUIT BREAKER

1618-13

5925-01-104-5938

5925 - Circuit Breakers

Decision Data Computer Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.400 inches nominal

  • Case Material

    plastic

  • Trip Release Method

    thermal single location

  • Actuator Function

    reset

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    3 quick disconnect, male

  • Body Style

    1a single pole type

  • Body Length

    1.140 inches nominal

  • Body Width

    0.570 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.000 inches nominal

  • Mounting Surface To Terminal End Distance

    2.260 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    27

  • Thread Series Designator

    uns

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 40.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    shunt trip single location

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 push button

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    40.0 ac and 40.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 24.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac and 4.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...