Technical Characteristics
-
~1
data on certain environmental and performance
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
-
Trip Release Method
magnetic second location
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac second location
-
Pole Quantity
4
-
Inclosure Protection Type For Which Designed
fungus resistant and explosion proof and moisture resistant
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.760 inches maximum
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct third location and 12.000 maximum at 200 pct third location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Terminal Type And Quantity
8 threaded stud
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct second location and 12.000 maximum at 200 pct second location
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
1.955 inches maximum
-
Trip Release Characteristic
time delay second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 second location
-
Internal Trip Release Configuration
series trip third location
-
Frequency In Hertz
400.0 second location
-
Main Contact Tripping Mechanism Type
trip free
-
Boss Height
0.165 inches maximum
-
Trip Release Characteristic
time delay third location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
-
Body Width
3.060 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Frequency In Hertz
400.0 third location
-
Trip Release Method
magnetic first location
-
Manual Actuator Type And Quantity
4 toggle
-
Test Data Document
18876-+55629-002 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Special Features
pole 4 shall be a dummy pole
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
0.760 inches maximum
-
Frequency In Hertz
400.0 first location
-
Circuit Protection Type
overcurrent first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct first location and 12.000 maximum at 200 pct first location
-
Actuator Function
trip-reset
-
Body Length
2.500 inches maximum
-
Mounting Surface To Terminal End Distance
2.491 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac third location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.070 inches maximum
-
Trip Release Method
magnetic third location
-
Circuit Protection Type
overcurrent second location
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Body Style
multipole-multiple actuator type
-
Circuit Protection Type
overcurrent third location
-
Internal Trip Release Configuration
series trip first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 first location
-
Trip Release Characteristic
time delay first location