121G165908A

Circuit Breakers

CIRCUIT BREAKER

121G165908A

5925-01-105-4407

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Current Rating And Type In Amps

    1.0 ac and 1.0 dc

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Overall Height

    11.468 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    9.875 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    3 alarm

  • Switch Terminal Type

    wire lead

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 120.0 dc

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    9.000 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100000.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Location And Position Designation

    internal at each pole

  • Maximum Continuous Load Current Rating Per Pole

    250.0 amperes ac all locations

  • Body Length

    12.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...