ETN6909-10

Circuit Breakers

CIRCUIT BREAKER

ETN6909-10

5925-01-105-4408

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +3090.0/+5825.0 ac all locations

  • Switch Current Rating And Type In Amps

    2.0 ac and 2.0 dc

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    9.000 inches nominal

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100000.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Overall Height

    9.687 inches nominal

  • Unpackaged Unit Weight

    45.000 pounds

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes ac all locations

  • Body Length

    17.938 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Voltage Rating And Type In Volts

    450.0 ac and 120.0 dc

  • Center To Center Distance Between Terminals Parallel To Length

    15.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    17.000 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.