532514-18

Circuit Breakers

CIRCUIT BREAKER

532514-18

5925-01-106-6726

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Boss Height

    0.115 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct all locations and 0.550 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 2000.0 dc all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Body Width

    2.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations and 50.0 amperes dc all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Terminal Type And Quantity

    12 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.810 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 60.0 dc all locations

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.460 inches nominal

  • Internal Trip Release Configuration

    relay trip all locations

  • Body Length

    2.270 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Mounting Surface To Terminal End Distance

    2.510 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...