D50-1002

Relays and Solenoids

RELAY,ELECTROMAGNETIC

D50-1002

5945-01-106-6736

5945 - Relays and Solenoids

Dri Relays Inc.

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Nominal Operating Current Rating And Type

    120.0 milliamperes dc single winding

  • Mounting Facility Type And Quantity

    2 unthreaded hole single mounting facility

  • Nonpile-Up Main Contact Arrangement

    1 pole, single throw, normally open, double make, momentary action and 1 pole, single throw, normally closed, double break, momentary action

  • Unthreaded Mounting Hole Diameter

    0.196 inches minimum single mounting facility and 0.202 inches maximum single mounting facility

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    2.365 inches minimum single mounting facility and 2.385 inches maximum single mounting facility

  • Storage Type

    general purpose warehouse

  • Overall Width

    1.090 inches minimum and 1.150 inches maximum

  • Environmental Protection

    hermetic

  • Arc Quenching Method

    air

  • Winding Quantity

    1

  • Overall Height

    2.365 inches minimum and 2.385 inches maximum

  • Terminal Type And Quantity

    5 screw all functions

  • Case Material

    metal

  • Main Contact Load Current Rating At Maximum Rated Voltage

    10.0 amperes dc lamp load

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes dc inductive load

  • Purpose For Which Designed

    general

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes dc resistive load

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Coil Quantity

    1

  • Time Delay

    0.04 seconds maximum fixed release time

  • Overall Length

    2.780 inches minimum and 2.840 inches maximum

  • Main Contact Maximum Voltage Rating In Volts

    28.0 dc

  • Main Contact Load Current Rating At Maximum Rated Voltage

    20.0 amperes dc motor load

  • Time Delay

    0.025 seconds maximum fixed operate time

  • Cubic Measure

    7.789 cubic inches

  • Duty Type

    continuous

  • Mounting Facility Pattern

    in-line single mounting facility

  • Features Provided

    coil voltage suppression and polarized

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...