78200225-001
Circuit Breakers
CIRCUIT BREAKER
78200225-001
Getronics Government Solutions Llc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
trip-reset
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.510 inches minimum and 1.675 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Terminal Type And Quantity
4 screw
-
Mounting Facility Type And Quantity
4 threaded hole
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Unpackaged Unit Weight
6.000 ounces
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
6.5 dc first location
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Special Features
pole one is a switch only
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
Body Width
1.515 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant and shockproof and vibrationproof
-
Internal Trip Release Configuration
relay trip first location
-
Case Material
plastic
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Boss Height
0.115 inches minimum and 0.145 inches maximum
-
Reset Method
manual
-
Frequency In Hertz
50.0 second location or 60.0 second location
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Pole Quantity
2
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac second location
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Circuit Protection Type
overcurrent all locations
-
Special Handling Feature
magnetic
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Fragility Factor
moderately rugged