M55629/6-040

Circuit Breakers

CIRCUIT BREAKER

M55629/6-040

5925-01-109-1710

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Width

    2.156 inches minimum and 2.344 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Body Style

    multipole-multiple actuator type

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Length

    2.510 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Frequency In Hertz

    400.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...