SM601BA40A1
Circuit Breakers
CIRCUIT BREAKER
SM601BA40A1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Body Style
rectangular dimensional envelope
-
Switch Location And Position Designation
internal at pole three
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Internal Trip Release Configuration
series trip all locations
-
Overall Length
4.250 inches nominal
-
Switch Voltage Rating And Type In Volts
115.0 ac and 28.0 dc
-
Trip Delay Time In Seconds Per Rated Continuous Current
16.000 minimum at 200 pct all locations and 80.000 maximum at 200 pct all locations
-
Switch Contact Arrangement
single pole, double throw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3600.0 ac all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Overall Height
3.250 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Frequency In Hertz
400.0 all locations
-
Overall Width
3.250 inches nominal
-
Switch Terminal Type
pin
-
Unthreaded Mounting Hole Diameter
0.172 inches nominal
-
Switch Current Rating And Type In Amps
3.0 ac and 3.0 dc
-
Auxiliary Switch Function And Quantity
1 alarm
-
Unpackaged Unit Weight
2.250 pounds
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations
-
Reset Method
automatic
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Terminal Type And Quantity
6 threaded stud