Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.938 inches nominal
-
Body Width
2.070 inches nominal
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Inclosure Type
encased
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Body Height
1.530 inches nominal
-
Overall Length
7.350 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
6.0 1st radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 2nd radio interference
-
Operating Current Rating Per Function In Amps
6.0 2nd radio interference
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Current Rating Per Function In Amps
6.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Special Features
three filtered functions
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 3rd radio interference 3rd function
-
Functional Terminal Type And Quantity
2 wire lead input 1st function
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference 1st function
-
Maximum Temp Rise
40.0 deg celsius
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Functional Terminal Type And Quantity
3 wire lead output 2nd function
-
Operating Temp Range
-10.0/+40.0 deg celsius
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Maximum Dielectric Withstanding Ac Rms Voltage
500.0 volts at sea level
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function
-
Body Length
2.560 inches nominal
-
Maximum Voltage Drop Per Function
2.5 volts ac 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference