Technical Characteristics

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    6 clip

  • Special Features

    115 vac,60 hz undervoltage trip device included

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +2000.0/+6000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    14.250 inches nominal

  • Body Width

    9.625 inches nominal

  • Arc Quenching Method

    air

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    600.0 amperes ac all locations

  • Body Height

    4.750 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Body Length

    16.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Boss Height

    0.375 inches nominal

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Precious Material And Location

    contacts silver

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and vibration resistant

  • Center To Center Distance Between Terminals Parallel To Length

    14.250 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    75000.0 ac all locations

  • Unpackaged Unit Weight

    68.000 pounds

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...