Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Case Material

    plastic

  • Unpackaged Unit Weight

    11.100 ounces

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Body Width

    2.265 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Frequency In Hertz

    50.0 or b60.0

  • Internal Trip Release Configuration

    series trip

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Method

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    2.490 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...