MIL-PRF-55629/6

Circuit Breakers

CIRCUIT BREAKER

MIL-PRF-55629/6

5925-01-112-0650

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    3 toggle

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    2.479 inches minimum and 2.510 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • ~1

    data on certain environmental and performanc

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Mounting Surface To Terminal End Distance

    2.522 inches minimum and 2.553 inches maximum

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Width

    2.205 inches minimum and 2.285 inches maximum

  • Trip Release Method

    magnetic all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Body Style

    multipole-multiple actuator type

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.