XT-13040A
Coils and Transformers
TRANSFORMER,POWER
XT-13040A
Rca Corp Government And Commercial
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
7.620 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
6.750 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
4.750 inches nominal
-
Overall Height
4.250 inches maximum
-
Overall Width
5.880 inches maximum
-
Mounting Slot Width
0.312 inches nominal
-
Frequency Rating
47.0 hertz minimum and 63.0 hertz maximum
-
Input-Output Phase Relationship
single phase to single phase
-
Maximum Operating Temp
55.0 deg celsius
-
Winding Operating Current
2.5 amperes ac maximum
-
Winding Operating Current
20.0 milliamperes ac maximum
-
Unpackaged Unit Weight
25.000 pounds
-
Terminal Type And Quantity
18 tab,solder lug
-
Reliability Indicator
not established
-
Winding Shielding Method
internal shield grounded to core
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Mounting Method
flange and slot
-
Cooling Method
forced air
-
Winding Function And Quantity
2 primary and 2 secondary
-
Winding Tap Location
center tap
-
Winding Tap Location
multiple taps w/center tap
-
Winding Operating Voltage
117.00 ac volts nominal
-
Winding Operating Voltage
387.50 ac volts nominal and 438.50 ac volts nominal and 469.00 ac volts nominal and 485.20 ac volts nominal and 569.80 ac volts nominal and 585.00 ac volts nominal and 616.50 ac volts nominal and 667.50 ac volts nominal and 1055.00 ac volts nominal