205-111-1REC3-42F-4-502-M-O
Circuit Breakers
CIRCUIT BREAKER
205-111-1REC3-42F-4-502-M-O
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
2.250 inches maximum
-
Switch Terminal Type
tab, solder lug
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Features Provided
sliding bar interlock
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Switch Current Rating And Type In Amps
10.0 ac
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Ultimate Trip Time Per Pole In Seconds
5.000 minimum all locations and 60.000 maximum all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches maximum
-
Body Style
multipole-multiple actuator type
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations
-
Switch Contact Arrangement
single pole, double throw
-
Mounting Facility Type And Quantity
6 threaded hole
-
Special Features
black handle
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.200 maximum at 400 pct all locations and 0.400 minimum at 400 pct all locations and 2.200 minimum at 200 pct all locations and 0.012 minimum at 600 pct all locations and 20.000 maximum at 200 pct all locations and 0.200 maximum at 600 pct all locations
-
Switch Location And Position Designation
external at pole one
-
Main Contact Tripping Mechanism Type
trip free
-
Inclosure Protection Type For Which Designed
moisture resistant and fungus proof and dustproof and salt spray proof
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations
-
Mounting Surface To Terminal End Distance
2.506 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Case Material
plastic
-
Body Length
2.490 inches nominal
-
Terminal Type And Quantity
6 threaded stud