AM3-A9-A8-A8-A-20-20
Circuit Breakers
CIRCUIT BREAKER
AM3-A9-A8-A8-A-20-20
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Ultimate Trip Time Per Pole In Seconds
10.000 minimum all locations
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Switch Location And Position Designation
internal at pole one
-
Auxiliary Switch Function And Quantity
1 control
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct all locations and 3.000 minimum at 200 pct all locations and 0.500 minimum at 400 pct all locations and 2.000 maximum at 400 pct all locations
-
Storage Type
general purpose warehouse
-
Features Provided
sliding bar interlock and high inrush protection
-
Switch Current Rating And Type In Amps
10.0 ac
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Body Width
2.240 inches minimum and 2.251 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Mounting Facility Type And Quantity
6 threaded hole