CD6-A2A3A3A3A3A3-DV-25-240-1

Circuit Breakers

CIRCUIT BREAKER

CD6-A2A3A3A3A3A3-DV-25-240-1

5925-01-113-7793

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.844 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Width

    6.192 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and corrosion resistant and shock resistant and humidity resistant and vibration resistant

  • Unthreaded Mounting Hole Diameter

    0.156 inches nominal

  • Thread Quantity Per Inch

    32

  • Body Style

    multipole-multiple actuator type

  • Pole Quantity

    6

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Special Features

    barrier,0.120 in. h,on left side

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one, two, three, four, five, and six linked

  • Mounting Facility Type And Quantity

    12 threaded stud and 12 unthreaded hole

  • Terminal Type And Quantity

    12 threaded stud

  • Boss Height

    0.218 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches minimum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Manual Actuator Type And Quantity

    6 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...