6607A-7-99
Switches
SWITCH,PRESSURE
6607A-7-99
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
outlet connection
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Style Designator
cylindrical
-
Err Default
err default
-
Contact Adjustment Type
external deactuation point screw and external actuation point screw
-
End Item Identification
basic device 50237
-
Pressure Connector Type
flare, threaded internal single connection
-
Media For Which Designed
gas
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 275.0 deg fahrenheit maximum
-
Thread Class
3b single pressure connection
-
Overall Length
3.340 inches maximum
-
Thread Series Designator
unf single pressure connection
-
Terminal Type
screw
-
Hazardous Locations/Environmental Protection
general purpose-nema type 1
-
Contact Stimulus Rating
125.00 differential point nominal pounds per square inch gage
-
Contact Adjustment Range
+400.00/+1000.00 actuation point pounds per square inch gage and +275.00/+875.00 deactuation point pounds per square inch gage
-
Inside Diameter
0.438 inches nominal single connection
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Overall Diameter
1.380 inches maximum
-
Nominal Thread Size
0.438 inches single pressure connection
-
Features Provided
electrical access port
-
Body Length
2.260 inches maximum
-
Pressure Switch Type
gage
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Load Current Rating
5.0 amperes resistive load single voltage and 2.5 amperes inductive load single voltage
-
Contact Action Stimulus
increase