2335-127-3
Switches
SWITCH,PRESSURE
2335-127-3
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Action Stimulus
increase
-
Style Designator
cylindrical
-
Terminal Type
connector, receptacle
-
Proof Pressure
484.00 pounds per square inch gage
-
Contact Load Current Rating
100.0 milliamperes inductive load single voltage
-
Hazardous Locations/Environmental Protection
explosion proof
-
Media For Which Designed
gas
-
Overall Length
3.500 inches nominal
-
Thread Series Designator
unf single pressure connection
-
Contact Stimulus Rating
200.00 deactuation point nominal pounds per square inch gage and 250.00 actuation point nominal pounds per square inch gage and 50.00 differential point nominal pounds per square inch gage
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 300.0 deg fahrenheit maximum
-
Features Provided
electrical box connector
-
End Item Identification
bleed air sys
-
Overall Diameter
1.120 inches maximum
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Pressure Connector Type
flared, threaded external single connection
-
Mounting Method
input port
-
Nominal Thread Size
0.438 inches single pressure connection
-
Pressure Switch Type
gage