CD3-A3-AB-5-480-2

Circuit Breakers

CIRCUIT BREAKER

CD3-A3-AB-5-480-2

5925-01-116-5462

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches minimum and 1.058 inches maximum

  • External Actuator Linkage Arrangement

    one and two linked

  • Unpackaged Unit Weight

    2.000 pounds

  • Terminal Type And Quantity

    4 threaded stud

  • Manual Actuator Type And Quantity

    3 toggle

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches minimum and 1.058 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Body Width

    3.046 inches minimum and 3.110 inches maximum

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Mounting Slot Width

    0.178 inches nominal

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.578 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...