APGN-666-1-42-752

Circuit Breakers

CIRCUIT BREAKER

APGN-666-1-42-752

5925-01-118-6345

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.480 inches minimum and 0.510 inches maximum

  • Body Width

    2.265 inches maximum

  • Iii Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Iii Unpackaged Unit Weight

    9.000 ounces

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Iii Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Iii Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip all locations

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    6 screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...