Technical Characteristics

  • Body Style

    4a single pole type

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.875 inches maximum

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • ~1

    stant and salt spray proof

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and humidity resistant and moisture resi

  • Unpackaged Unit Weight

    2.500 ounces

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.550 inches minimum and 1.570 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.650 inches minimum and 1.670 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    unc

  • Frequency In Hertz

    50.0 or 60.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 20.000 maximum at 200 pct single location

  • Actuator Position Designation

    at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    2 threaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...