GC885EH8

Circuit Breakers

CIRCUIT BREAKER

GC885EH8

5925-01-119-6172

5925 - Circuit Breakers

Northrop Grumman Systems Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Inclosure Protection Type For Which Designed

    shock resistant and salt spray proof and moisture resistant and fungus resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Body Style

    single pole type

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Width

    0.750 inches maximum

  • Unpackaged Unit Weight

    3.700 ounces

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Thread Series Designator

    unc

  • Mounting Surface To Terminal End Distance

    2.490 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Special Features

    inertial delay included

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Switch Contact Arrangement

    single pole, double throw

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...