M39019/02-246

Circuit Breakers

CIRCUIT BREAKER

M39019/02-246

5925-01-119-6174

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.669 inches minimum and 1.700 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    9.0 amperes ac single location and 9.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    50.0 grams

  • Test Data Document

    81349-mil-c-39019 specification

  • Specification/Standard Data

    81349-mil-c-39019/2 government specification

  • Body Style

    2a single pole type

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Body Width

    0.594 inches minimum and 0.625 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Pole Quantity

    1

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...