HE3-C9C8C8-6-2

Circuit Breakers

CIRCUIT BREAKER

HE3-C9C8C8-6-2

5925-01-120-3837

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonturn Device Length

    0.130 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Bushing Length

    0.380 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Body Width

    1.875 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Thread Series Designator

    unef

  • Frequency In Hertz

    400.0 all locations

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.500 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Case Material

    metal

  • Nonturn Device Radius

    0.625 inches nominal

  • Body Style

    multipole-single actuator type

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Actuator Position Designation

    at pole two

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

  • Nonturn Device Diameter

    0.140 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...