8939910-2
Coils and Transformers
COIL,RADIO FREQUENCY
8939910-2
COIL,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Quality Factor
200 minimum single component single winding
-
Turn Quantity
5-1/2 single component single winding
-
Winding Conductor Size
0.04030 inches american wire gage single component single winding
-
Mounting Method
terminal single group
-
Coil Form Type
solid single component
-
Reliability Indicator
not established
-
Terminal Type And Quantity
2 wire lead
-
Inductance Rating
0.22 microhenries nominal single component single winding
-
Body Outside Diameter
0.540 inches maximum
-
Inclosure Type
fully inclosed
-
Winding Operating Current
10.0 milliamperes maximum of standard range b and better drop siding single component single winding
-
Frequency At Which Inductance And Quality Factor Applies (Non-Core)
25.0 megahertz single component single winding
-
Body Length
0.875 inches maximum
-
Rating Method
electrical single component single winding and winding turns single component single winding