AP411-1R5676-1
Circuit Breakers
CIRCUIT BREAKER
AP411-1R5676-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Manual Actuator Type And Quantity
1 toggle
-
Circuit Protection Type
overvoltage first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac second location
-
Frequency In Hertz
60.0 all locations
-
Trip Release Characteristic
time delay second location
-
Body Length
1.500 inches maximum
-
Internal Trip Release Configuration
series trip third location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac second location
-
Switch Current Rating And Type In Amps
0.5 ac
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Special Features
no current on pole one
-
Trip Release Characteristic
time delay third location
-
Thread Series Designator
unef
-
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Terminal Type
quick disconnect, male
-
Body Width
1.875 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac third location
-
Internal Trip Release Configuration
relay trip first location
-
Switch Voltage Rating And Type In Volts
125.0 ac
-
Bushing Length
0.332 inches minimum and 0.375 inches maximum
-
Terminal Type And Quantity
6 wire hook and 2 quick disconnect, male
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac third location
-
Nonturn Device Diameter
0.250 inches nominal
-
Pole Quantity
3
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac first location
-
Reset Method
manual
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct second location and 9.000 maximum at 200 pct second location
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Switch Location And Position Designation
internal at pole three
-
Storage Type
general purpose warehouse
-
Inclosure Protection Type For Which Designed
moisture resistant and shockproof and hermetically sealed and salt spray proof and vibrationproof
-
Actuator Function
trip-reset
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct third location and 9.000 maximum at 200 pct third location
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.595 inches minimum and 0.656 inches maximum
-
Actuator Position Designation
at pole two
-
Switch Contact Arrangement
single pole, double throw
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Body Style
multipole-single actuator type
-
Trip Release Characteristic
instantaneous first location
-
Case Material
metal