A-3798
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
A-3798
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Dielectric Withstanding Dc Voltage
800.0 volts at sea level
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.968 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
0.5 volts ac 1st radio interference
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Current Rating Per Function In Amps
0.6 1st radio interference
-
Body Height
2.000 inches nominal
-
Maximum Voltage Drop Per Function
0.5 volts ac 2nd radio interference
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Operating Current Rating Per Function In Amps
0.6 2nd radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Operating Voltage Rating And Type Per Function
230.0 volts ac 1st radio interference 1st function
-
Body Length
1.000 inches nominal
-
Input Terminal Manufacturer Code
97814
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Overall Height
2.187 inches nominal
-
Functional Terminal Type And Quantity
6 tab, solder lug output 2nd function
-
Inclosure Type
hermetically sealed
-
Input Terminal Identification
8001-16s-1p
-
Functional Terminal Type And Quantity
1 connector, receptacle input-ground 1st function
-
Body Width
1.380 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Overall Length
1.670 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
230.0 volts ac 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference