203-13-4451-3

Circuit Breakers

CIRCUIT BREAKER

203-13-4451-3

5925-01-122-7569

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac second location

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Special Features

    weapon system essential

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Body Height

    1.770 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Internal Trip Release Configuration

    series trip first location

  • Terminal Type And Quantity

    5 quick disconnect, male

  • Mounting Facility Type And Quantity

    4 clip

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    magnetic-hydraulic first location

  • Body Width

    1.540 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic second location

  • End Item Identification

    missile,minuteman lgm-30; mx peacekeeper

  • Internal Trip Release Configuration

    shunt trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...