11-0402-01
Switches
SWITCH,PRESSURE
11-0402-01
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Contact Voltage Rating In Volts
240.0 ac at sea level first voltage
-
Thread Series Designator
unc all threaded hole
-
Media For Which Designed
gas or liquid
-
Pressure Connector Type
beveled, butt weld single connection
-
Contact Voltage Rating In Volts
120.0 ac at sea level second voltage
-
Contact Stimulus Rating
32.00 actuation point nominal pounds per square inch gage and 20.00 deactuation point nominal pounds per square inch gage and 12.00 differential point nominal pounds per square inch gage
-
Contact Load Current Rating
20.0 amperes resistive load second voltage
-
Mounting Facility Pattern
two position in-line
-
Nominal Thread Size
0.138 inches all threaded hole
-
Features Provided
capillary tube end seal connection
-
Mounting Method
base and threaded hole
-
Outside Diameter
0.250 inches nominal single connection
-
Contact Load Current Rating
8.3 amperes resistive load first voltage
-
Terminal Type
tab, solder lug
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Contact Action Stimulus
increase
-
Thread Quantity Per Inch
32 all threaded hole
-
Pressure Switch Type
gage
-
End Item Identification
hull obrp
-
Distance Between Mounting Facility Centers
0.690 inches nominal