NF20980
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
NF20980
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
1.25 volts ac 2nd radio interference
-
Overall Length
6.188 inches nominal
-
Special Features
two filtered functions
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches nominal
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
2 turret output 2nd function
-
Overall Width
3.750 inches nominal
-
Overall Height
2.188 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
3.0 2nd radio interference
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Dielectric Withstanding Dc Voltage
250.0 volts at sea level
-
Body Length
5.375 inches nominal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Voltage Drop Per Function
1.25 volts ac 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.594 inches nominal
-
Features Provided
magnetic case
-
Body Width
3.000 inches nominal
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 1st radio interference 1st function
-
Unthreaded Mounting Hole Diameter
0.186 inches nominal
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Functional Terminal Type And Quantity
2 turret input 1st function