Technical Characteristics
-
Mounting Slot Width
0.104 inches nominal
-
Body Diameter
0.660 inches maximum
-
Overall Length
1.477 inches minimum and 1.497 inches maximum
-
Style Designator
disc w/flange
-
Distance Between Mounting Facility Centers
0.937 inches minimum and 0.999 inches maximum
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Mounting Method
bracket and slot
-
Features Provided
hermetically sealed case
-
Terminal Type
tab, solder lug
-
Temp Sensing Element Type
internal sensor
-
Overall Height
0.300 inches maximum
-
Contact Load Current Rating
2.0 amperes resistive load second voltage and 1.0 amperes inductive load second voltage and 1.0 amperes lamp load second voltage
-
Media For Which Designed
gas or liquid
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Frequency In Hertz
60.0 first voltage
-
Specification/Standard Data
81349-mil-s-24236/20 government specification
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
~1
data on certain environmental and performanc
-
~1
degrees fahrenheit
-
Test Data Document
81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Contact Stimulus Rating
2.00 differential point minimum degrees fahrenheit and 135.00 deactuation point minimum degrees fahrenheit and 140.00 actuation point nominal degrees fahrenheit and 138.00 deactuation point maximum degrees fahrenheit and 5.00 differential point maximum
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Body Height
0.300 inches maximum
-
Mounting Facility Pattern
two position in-line
-
Operating Temp Rating
-10.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum
-
Contact Load Current Rating
1.5 amperes inductive load first voltage and 2.0 amperes resistive load first voltage and 500.0 milliamperes lamp load first voltage
-
Contact Action Stimulus
increase