APL-11-1-40-103 M

Circuit Breakers

CIRCUIT BREAKER

APL-11-1-40-103 M

5925-01-124-8078

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.050 nominal at 150 pct all locations

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Thread Series Designator

    unf

  • Boss Height

    0.150 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.575 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overvoltage all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Inclosure Protection Type For Which Designed

    salt spray proof and moisture resistant and fungus resistant and shockproof and vibrationproof

  • Ultimate Trip Time Per Pole In Seconds

    0.050 nominal all locations

  • Frequency In Hertz

    400.0 all locations

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 85.0 deg celsius maximum all locations

  • Terminal Type And Quantity

    4 threaded stud

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Case Material

    plastic

  • Body Length

    2.490 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...