114-216-103

Circuit Breakers

CIRCUIT BREAKER

114-216-103

5925-01-125-0402

5925 - Circuit Breakers

Tyco Electronics Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    5a single pole type

  • Overall Length

    1.344 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.000 inches nominal

  • Mounting Surface To Terminal End Distance

    1.875 inches nominal

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Overall Width

    0.930 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.969 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.125 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 32.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 300.0 dc

  • Trip Release Method

    thermal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 30.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Switch Current Rating And Type In Amps

    3.0 ac and 1.0 dc

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    16.0 amperes ac single location and 16.0 amperes dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Switch Terminal Type

    pin

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 1.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab, solder lug

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...