211C223-156
Switches
SWITCH,PRESSURE
211C223-156
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 275.0 deg fahrenheit maximum
-
Sensing Element Burst Pressure
7500.00 pounds per square inch gage
-
Overall Diameter
0.880 inches nominal
-
Overall Length
3.750 inches maximum
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Terminal Type
connector, receptacle
-
Nonpile-Up Contact Arrangement
2 pole, double throw, one position momentary
-
Style Designator
cylindrical
-
Mounting Method
inlet connection
-
Contact Action Stimulus
increase
-
Body Diameter
0.800 nominal mils
-
Contact Voltage Rating In Volts
18.0 dc at sea level first voltage
-
Outside Diameter
0.438 inches nominal single connection
-
Body Length
2.370 inches nominal
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Pressure Switch Type
gage
-
Contact Load Current Rating
3.0 amperes inductive load second voltage and 4.0 amperes resistive load second voltage and 0.4 amperes lamp load second voltage
-
Proof Pressure
4500.00 pounds per square inch gage
-
Contact Load Current Rating
3.0 amperes inductive load first voltage and 4.0 amperes resistive load first voltage and 0.4 amperes lamp load first voltage
-
Contact Stimulus Rating
1950.00 deactuation point minimum pounds per square inch gage and 2400.00 actuation point maximum pounds per square inch gage and 2000.00 deactuation point maximum pounds per square inch gage
-
Nominal Thread Size
0.438 inches single pressure connection
-
Pressure Connector Type
flareless, threaded external single connection
-
Media For Which Designed
gas or liquid
-
Thread Class
3a single pressure connection
-
Thread Series Designator
unjf single pressure connection