MIL-PRF-6106

Relays and Solenoids

RELAY,ELECTROMAGNETIC

MIL-PRF-6106

5945-01-127-3807

5945 - Relays and Solenoids

Military Specifications

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    2 unthreaded hole single mounting facility

  • Main Contact Load Current Rating At Maximum Rated Voltage

    4.0 amperes ac motor load and 4.0 amperes dc motor load

  • Overall Height

    1.010 inches maximum

  • Operating Voltage Rating And Type At Specified Temp

    42.0 volts teardrop, two holes type 4f single winding

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Main Contact Load Current Rating At Maximum Rated Voltage

    10.0 amperes ac resistive load and 10.0 amperes dc resistive load

  • Features Provided

    coil voltage suppression and polarized

  • Mounting Facility Pattern

    in-line single mounting facility

  • Duty Type

    continuous

  • Unthreaded Mounting Hole Diameter

    0.157 inches minimum single mounting facility and 0.161 inches maximum single mounting facility

  • Time Delay

    10.00 seconds maximum fixed operate and release time

  • Coil Quantity

    1

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.406 inches nominal single mounting facility

  • Overall Width

    0.525 inches maximum

  • Specification/Standard Data

    96906-ms27401 government standard

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Terminal Type And Quantity

    8 wire hook all functions

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes ac lamp load and 2.0 amperes dc lamp load

  • Overall Length

    1.718 inches maximum

  • Winding Quantity

    1

  • Environmental Protection

    hermetic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.