D013559
Relays and Solenoids
RELAY,ELECTROMAGNETIC
D013559
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes dc lamp load
-
Main Contact Maximum Voltage Rating In Volts
30.0 dc
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Mounting Facility Type And Quantity
2 unthreaded hole single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes dc motor load
-
Terminal Type And Quantity
10 pin all functions
-
Environmental Protection
hermetic
-
Overall Length
1.718 inches maximum
-
Unthreaded Mounting Hole Diameter
0.150 inches nominal single mounting facility
-
Overall Height
1.395 inches maximum
-
Winding Quantity
2
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, both positions maintained
-
Overall Width
0.525 inches maximum
-
Nominal Operating Current Rating And Type
55.0 milliamperes dc all windings
-
Coil Quantity
2
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes dc inductive load
-
Winding Dc Resistance Rating
600.0 ohms nominal single winding
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f all windings
-
Features Provided
coil voltage suppression and latching contacts and polarized
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.421 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes dc resistive load