AM33MG6-40-250VAC400C15

Circuit Breakers

CIRCUIT BREAKER

AM33MG6-40-250VAC400C15

5925-01-128-4370

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 threaded stud

  • Frequency In Hertz

    400.0

  • External Actuator Linkage Arrangement

    one and two linked

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Characteristic

    time delay

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Specification/Standard Data

    81349-mil-c-55629/3 government specification

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629 specification

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 1.900 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Position Designation

    at each pole

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Case Material

    plastic

  • Body Length

    2.510 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Body Width

    1.437 inches minimum and 1.563 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...